Category
ZK200 200V 0.75kw V/F contriol variable speed drive VSD
ZK200-2S-0.75GB
Rated Power:0.75kw
Rated Voltage: 220V
Rated current:4A
Control Mode: V/F, SVC in open loop, close loop vector control
Type: AC inverter
Overload capacity: G type:150% - 60 seconds, P type:120% - 60 seconds
Rated Voltage: 220V
Rated current:4A
Control Mode: V/F, SVC in open loop, close loop vector control
Type: AC inverter
Overload capacity: G type:150% - 60 seconds, P type:120% - 60 seconds
Quantity:
ZK200 ZK200-2S-0.75GB 0.75kw variable speed drive
Variable speed drives, also known as variable frequency inverter or VSD.
With market demands increasingly centered around smaller power and size requirements along with hassle-free speed regulation, the mini variable speed drive has been created to fulfill those needs. ZK200, a compact variable speed drive, boasts a small size with a remarkable high capacity, high power density, top-notch EMC specification design, and unbeatable reliability.


ZK200 model list
| Model | Power rating | Output current | Input current | Matched motor | Brake unit |
| (kW) | (A) | (A) | (kW) | ||
| single-phase 220V | |||||
| ZK200-2S-0.4GB | 0.4 | 2.3 | 5 | 0.4 | Inbuilt |
| ZK200-2S-0.75GB | 0.75 | 4 | 8.2 | 0.75 | |
| ZK200-2S-1.5GB | 1.5 | 7 | 14 | 1.5 | |
| ZK200-2S-2.2GB | 2.2 | 9.6 | 23 | 2.2 | |
| three-phase 220V | |||||
| ZK200-2T-0.4GB | 0.4 | 2.3 | 4 | 0.4 | Inbuilt |
| ZK200-2T-0.75GB | 0.75 | 4 | 4.8 | 0.75 | |
| ZK200-2T-1.5GB | 1.5 | 7 | 8.8 | 1.5 | |
| ZK200-2T-2.2GB | 2.2 | 9.6 | 12 | 2.2 | |
| three-phase 380V | |||||
| ZK200-4T-0.4GB | 0.4(0.75) | 1.5(2.5) | 1.9(3.5) | 0.4(0.75) | Inbuilt |
| ZK200-4T-0.75GB | 0.75(1.5) | 2.5(3.8) | 3.5(4.6) | 0.75(1.5) | |
| ZK200-4T-1.5GB | 1.5(2.2) | 3.8(5.1) | 4.6(6.3) | 1.5(2.2) | |
| ZK200-4T-2.2GB | 2.2(3.0) | 5.1(7.1) | 6.3(8.6) | 2.2(3.0) | |
| ZK200-4T-4.0GB | 4.0(5.5) | 9.5(13) | 12.1(16.8) | 4.0(5.5) | |
| ZK200-4T-5.5GB | 5.5(7.5) | 13(17) | 16.8(22) | 5.5(7.5) | |
| ZK200-4T-7.5GB | 7.5(11) | 17(25) | 22(32.5) | 7.5(11) | |
| ZK200-4T-11GB | 11(15) | 25(32) | 32.5(41.5) | 11(15) | |
| ZK200-4T-15GB | 15(18.5) | 32(37) | 41.5(49.6) | 15(18.5) | |
| ZK200-4T-18.5GB | 18.5(22) | 37(45) | 49.6(59) | 18.5(22) | |
| ZK200-4T-22GB | 22(30) | 45(60) | 59(65) | 22(30) | |
ZK200 0.75KW technical data
| Power input | Rated input voltage | 200V Voltage Class:single/three-phase 200V ~ 240V |
| 400V Voltage Class:Three-phase 380V~440V | ||
| Frequency | 50Hz/60Hz, tolerance ±5% | |
| Voltage range | -15%~+15% | |
| Voltage out-of-balance rate<3%, distortion rate as per the requirements of IEC61800-2 | ||
| Rated input current | 7A | |
| Power output | Applicable motor (kW) | 0.75KW |
| Rated current (A) | 4A | |
| Output voltage (V) | 3-phase:0%~rated input voltage, error < ±3% | |
| Output frequency (Hz) | 0.00%~600.00Hz; unit:0.01Hz | |
| Overload capacity | G type:150% - 60 seconds, P type:120% - 60 seconds | |
| Control characteristics | Control mode | V/f control |
| Sensorless vector control (SVC) | ||
| Range of speed regulation | 1:200 (Sensor-less vector control ) | |
| Speed accuracy | ±0.5% (Sensor-less vector control ) | |
| Torque control accuracy | 5%(SVC) | |
| Torque increase | Automatic torque lifting; Manual torque increased by 0.1-30.0% | |
| Starting torque | 0.25Hz:150% (Sensor-less vector control ) | |
| Basic functions | Output frequency | 0.00~600.00Hz |
| ACC/DEC time | 0.00~30000s | |
| Carrier frequency | 0.5kHz~16kHz | |
| Frequency setting | Digital setting + Keyboard Control | |
| Communication | ||
| Analog setting | ||
| Terminal pulse setting | ||
| Motor | Started from starting frequency | |
| start-up methods | DC brake start-up | |
| Speed tracking start | ||
| Motor stop methods | Ramp to stop | |
| Free stop | ||
| Brake unit working voltage: | ||
| Dynamic braking capacity | 200V level:325-375V / 380V level:650V-810V | |
| Service time:0-100.0s; | ||
| DC brake capacity | DC brake start frequency:0.00~600.00Hz | |
| DC brake current:0.0~100.0% | ||
| DC brake time:0.0~100.00s | ||
| Input terminals | 4 digital inputs, one of which can be used for high-speed pulse input | |
| 1 analog inputs, which is voltage/current optional | ||
| Output terminals | 1 digital output terminal, 2 Relay output terminal,1 analog output ,Voltage and current outputs are optional, supporting 0~10V voltage or 0/4~20mA current outputs. | |
| Communication terminal | 1 channel RS485 communication (standard), can support up to 38400bps communication rate | |
| Featured functions | Parameter copy, parameter backup, common DC bus, parameters, flexible parameter displayed & hidden, various master & auxiliary setting and switchover, flying start, a variety of Accel/Decel curves optional, brake control, 16-step speed control programmable (2-step speed supports flexible frequency command), wobble frequency control, fixed length control, count function, three history faults, over excitation brake, over voltage stall protection, under voltage stall protection, restart on power loss, skip frequency, frequency binding, four kinds of Accel/Decel time, motor thermal protection, flexible fan control, process PID control, simple PLC, multi-functional key programmable, droop control, autotuning,field-weakening control, high-precision torque restraint, V/f separatedcontrol | |
| Protection functions | Refer to Chapter 6-Trouble Shooting | |
| Environment | Place of operation | Indoors, no direct sunlight, free from dust, corrosive gases, flammable gases, oil mist, water vapor, water drop or salt, etc. |
| Altitude | 0~2000m. De-rate 1% for every 100m when the altitude is above 1000 meters | |
| Ambient | -10℃~50℃, The rated output current should be derated | |
| temperature | 1% for every 1℃ when the ambient is 40℃~50℃ | |
| Relative humidity | 5~95%, no condensation | |
| Vibration | Less than 5.9m/s² (0.6g) | |
| Storage temperature | -20℃~+60℃ | |
| Others | Efficiency at rated Amps | Rated power 7.5kW and below:≥93% 11~22kW:≥ 95% |
| Installation | Standard: wall-mounted; Optional: 5.5kW and below DIN-Rail Mount, 7.5kW and above embedded installation | |
| IP grade | IP20 | |
| Cooling method | Forced air cooling,Natural cooling | |
Send Message