Category
ZK SU100 5.5KW Mppt solar pump controller
SU100-D3-5R5G-B
Brand Name: ZK
Model Number: SU100-D3-5R5G-B
Input Voltage: 250-800Vdc or 3phase 380Vac
Output Voltage: 380Vac, 480Vac operational
Rate current: 13A
Type: DC/AC Inverters
Output Frequency: 50HZ/60HZ
Mppt Efficiency: 99.7%
Motor type: PMSM and IM
Protection: 20 kinds of motor protection
Warranty: 18th months
Model Number: SU100-D3-5R5G-B
Input Voltage: 250-800Vdc or 3phase 380Vac
Output Voltage: 380Vac, 480Vac operational
Rate current: 13A
Type: DC/AC Inverters
Output Frequency: 50HZ/60HZ
Mppt Efficiency: 99.7%
Motor type: PMSM and IM
Protection: 20 kinds of motor protection
Warranty: 18th months
Quantity:
ZK SU100 SERIES SOLAR PUMP INVERTER
1. MPPT efficiency more than 99%.
2. Drives well all 1/3 phase AC pumps and PMSM in solar pumping system.
3. VMP of solar panel can set by manual or MPPT automatically tracking.
4. Solar DC & Grid AC power input,
5. Short circuit, over load, over current... motor production.
6. Dry run & Full water tank protection.
7. The PQ (power/flow) performance curve enables calculating the flow output from the pump
8. Ambient temperature for using: -10 to +50˚C.
9. Inverter Power range: 220V: 0.75KW to 75KW. 380V/440/460/480V: 0.75KW to 250KW.

| Item | Specification | |
| Power input | Voltage, frequency | D1: 90V DC to 400V DC or 110V±15% AC, 50/60Hz |
| D2:150V DC to 450V DC or 220V±15% AC, 50/60Hz | ||
| D3: 250V DC to 750V DC or 380V±15% AC, 50/60Hz | ||
| T3: 350V DC to 750V DC or 380V±15% AC, 50/60Hz | ||
| Allowable fluctuations | voltage unbalance rate:<3%; Frequency:±5%; aberration rate: as IEC61800-2 required | |
| Power factor | ≥0.94(with DC reactor) | |
| Efficiency | ≥96% | |
| Output | Output voltage | Output under rated condition: 3 phase, 0~input voltage, inaccuracy<5% |
| Output frequency range | G type:0~600Hz | |
| Output frequency accuracy | Max frequency ±0.5% | |
| Overload capacity | G type: 150% rated current/1 min, 180% rated current/10s, 200% rated current/0.5s | |
| Main control performance | Motor control mode | V/F without PG , VC without PG , VC with PG |
| Speed control range | Vector control without PG, rated load 1:100;Vector control with PG, rated load 1:1000; | |
| Steady speed accuracy | VC without PG: ≤2% rated synchronized speed; | |
| VC with PG: ≤0.05% rated synchronized speed | ||
| Starting torque | VC without PG: when 0.5Hz, 150% rated torque; | |
| VC with PG: when 0Hz, 200% rated torque | ||
| Torque response | VC without PG: ≤20ms; | |
| VC with PG: ≤10ms. | ||
| Frequency accuracy | Digit setting: max frequency×±0.01%; | |
| Analog setting: max frequency×±0.2% | ||
| Frequency resolution | Digital setting: 0.01Hz; | |
| Analog setting: maximum frequency × 0.05% | ||
Product basic functions | DC braking capacity | Starting frequency:0.00~50.00Hz; Braking time:0.0~60.0s; |
| Braking current:0.0~150.0% rated current | ||
| Torque boost capacity | Auto torque upgrade 0.0%~100.0%; | |
| Manual torque upgrade 0.0%~30.0% | ||
| V/F curve | 4 modes: one linearity torque characteristic curve ,one self-setting V/F curve mode, one drop torque characteristic curve (1.1- 2.0 powers),and square V/F curve mode. | |
| Acceleration/Deceleration curve | 2 modes: linear Acceleration/Deceleration and S curve Acceleration/Deceleration. | |
| 4 sets of ACC/DEC, time unit 0.01s selectable, longest time: 650.00s. | ||
| Rated output voltage | Rely on power supply voltage compensate function, while motor rated voltage is 100%, set it at the range of 50-100%(output can not over input voltage). | |
| Voltage auto-adjustment | While power supply voltage fluctuates, it can auto-keep constant output voltage. | |
| Auto energy-saving running | While under V/F control mode, according to load situation, auto-optimize output voltage to save energy. | |
| Standard functions | PID control, speed track, power off restart, jump frequency, upper/lower frequency limit control, program operation, multi- speed, RS485, analog output, frequency impulse output. | |
| Product | Frequency setting channels | Keyboard digital setting, keyboard potentiometer ,Analog voltage/current terminal AI1、AI2, Communication given and multi-channel terminal selection, Main and auxiliary channel combination, expansion card, supporting different modes switch. |
| basic functions | Feedback input channel | Voltage/Current Terminal AI1, Voltage/Current Terminal AI12, Communication |
| given, pulse input X5. | ||
| Running command channel | Operation panel given、external terminal given, communication given, expansion card given. | |
| Input command signal | Start, stop, FWD/REV, JOG, multi-step speed, reset, ACC/DEC time selection, frequency given channel selection, exterior fault alarm. | |
| Protective function | Overvoltage, under-voltage, current limit, over-current, overload, electric thermal relay, overheat, overvoltage stall, data protection, rapid speed protection, input/output phase failure protection. | |
| Environment | Install place | altitude ≤ 1000m,above 1000m down the rated amount, each increase of 100m down the rated mount of 1%;no condensation, ice ,rain, snow, hail; solar radiation below 700W/㎡, air pressure 70-106 kPa. |
| Temperature, humidity | -10 ~ + 50 ℃, derating above 40 ℃, maximum temperature 60 ℃ (no-load operation)5% to 95% RH (non-condensing) | |
| Vibration | When 9~200Hz, 5.9m/s2(0.6g) | |
| Storage temperature | -30 ~+60℃ | |
| Protection grade | IP20 | |
| Cooling method | Forced air cooling | |
| Inverter model | Dimensions(mm) | Installation(mm) | Mounting aperture | |||||
| W | H | D | D1 | W1 | H1 | |||
| SU100-D1-R75G-B | 89 | 190 | 135 | 144 | 79 | 180 | M4×2 | |
| SU100-D2-R75G-B | ||||||||
| SU100-D2-1R5G-B | ||||||||
| SU100-D3-R75G-B | ||||||||
| SU100-D3-1R5G-B | ||||||||
| SU100-D3-2R2G-B | ||||||||
| SU100-D1-1R5G-B | 106 | 230 | 148 | 157 | 96 | 219 | M4×3 | |
| SU100-D2-2R2G-B | ||||||||
| SU100-D2-004G-B | ||||||||
| SU100-D3-004G-B | ||||||||
| SU100-D3-5R5G-B | ||||||||
| SU100-D3-7R5G-B | ||||||||
| SU100-D3-11G-B | 130 | 275 | 160 | 169 | 115 | 260 | M5×3 | |
| SU100-D3-15G-B | ||||||||
| SU100-D3-18G-B | 155 | 335 | 191 | 200 | 141.5 | 320 | M5×4 | |
| SU100-D3-22G-B | ||||||||
| Inverter model | Dimensions (mm) | Installation(mm) | Mounting aperture | |||||
| W | H | H1 | D | W1 | H2 | |||
| SU100-T3-30G | 195 | 445 | 420 | 235 | 150 | 430 | 4-M6 | |
| SU100-T3-37G | ||||||||
| SU100-T3-45G | 240 | 560 | 520 | 310 | 176 | 544 | 4-M6 | |
| SU100-T3-55G | ||||||||
| SU100-T3-75G | ||||||||
| SU100-T3-90G | 270 | 640 | 582 | 350 | 200 | 620 | 4-M8 | |
| SU100-T3-110G | ||||||||
Send Message